ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2011 , Vol 6 , Num 1
Turkish Abstract Abstract PDF Similar Articles Mail to Author
The Assessement of Health Related Quality of Life in Glaucoma Patients
Olcayto ÇELİK1, Gül ARIKAN1, Üzeyir GÜNENÇ2, Güray ÇINGIL2
1Dokuz Eylül Üniversitesi, Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, İzmir, Uz. Dr.
2Dokuz Eylül Üniversitesi, Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, İzmir, Prof. Dr.
Purpose: To evaluate the relationship between clinical measures of visual function and quality of life in glaucoma patients.
Materials and Methods: Ninety primary open angle glaucoma patients were evaluated with using one utility test, the time trade-off test and one quality of life instrument, Modified Glau-QOL 17 Questionnaire. Their results were compared to Esterman binocular visual field (BVF) and other clinical test of their visual function.
Results: The mean score for the Modified Glau-QOL 17 Questionnaire was 77.6±12.4 (38.7-98.2) and 94.1±6.4 (69-100) for the Esterman BVF. The Esterman test correlated well with the overall Modified Glau-QOL 17 score (PCC=0.41; p=0.001) but only moderately with the time trade-off test (PCC=0.20; p=0.05). In addition, C/D ratio in the worse eye (PCC=-0.29; p=0.006), GSS 2 stage in the better eye (PCC=-0.27; p=0.01), glaucoma duration in years (PCC=0.23; p=0.03) and PSD in the better eye (PCC=-0.22; p=0.03) were correlated moderately with overall Modified Glau-QOL 17 score. Correlation between the time trade-off test and the overall Modified Glau-QOL 17 score was moderate (PCC=-0.32; p=0.002).
Conclusion: Time trade-off utility test do not correlate well with the Esterman test results and other clinical test of visual function than Modified Glau-QOL 17 questionnaire.
Keywords : Glaucoma, esterman binocular visual field, quality of life, time trade-off