ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2013 , Vol 8 , Num 2
Turkish Abstract Abstract PDF Similar Articles Mail to Author
The Comparison Between Torsional and Conventional Mode Phacoemulsification Methods in Senile Cataracts
Engin Bilge ÖZGÜRHAN1, Alper AĞCA1, Hasan ALTINKAYNAK1, Necip KARA1, Abdullah ÖZKAYA1, Ercüment BOZKURT2, Hüseyin DÜNDAR1, Ahmet DEMİROK3
1M.D., Beyoglu Eye Training and Reseach Hospital, İstanbul/TURKEY
2M.D. Associate Professor, Beyoglu Eye Training and Reseach Hospital, İstanbul/TURKEY
3M.D. Professor, Beyoglu Eye Training and Reseach Hospital, İstanbul/TURKEY
Purpose: To compare intraoperative parameters between conventionel and torsional phacoemulsification method for cataractous eyes.

Materials and Method: Thirty-six eyes of 36 patients suffering from age-related cataract were enrolled in this comparative randomized masked clinical study. The eyes had nuclear cataracts of grades III using the Lens Opacities Classification System III (LOCS III). Lenses that had developed cataract were divided into 2 equal pieces by phacoemulsification. Phacoemulsification was applied to first piece using conventional phaco and the second piece using torsional phaco technique. The pieces eaten by conventional mode phacoemulsification were named as group 1 and with torsional mode phacoemulsification as group 2. Parametric comparisons were made in terms of peroperative conventional and torsional total U/S time, total energy (U/STEPIP3%), CDE and aspiration time.

Conclusions: The total U/S, CDE and aspiration time parameters of the torsional phacoemulsification method are found to be lower than those of the conventional method in a statistically significant way (p=0.002, p=0.018, p=0.046, respectively).

Discussion: Torsional phacoemulsification technique is seen as a method more reliable and more effective method than the conventional method. Keywords : Longitudinal phaco, torsional phaco, aspiration time