ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2007 , Vol 2 , Num 2
Turkish Abstract Abstract PDF Similar Articles Mail to Author
Application of Optical Coherence Tomography in Glaucoma
Ali AYDIN1, Ahmet Hamdi BİLGE2
1GATA Haydarpaşa Eğitim Hastanesi Göz Hastalıkları Servisi, İstanbul, Yrd. Doç. Dr.
2GATA Haydarpaşa Eğitim Hastanesi Göz Hastalıkları Servis Şefi, İstanbul, Prof. Dr.
Glaucoma is a progressive optic neuropathy characterized by optic nerve damage and typical visual field defects due to retinal ganglion loss caused by a number of deseases affecting the eye. Although clinical examination and photography of the optic disc and retinal nerve fiber layer (RNFL) have been considered as sensitive tests for detecting glaucomatous damage and its progression, they are highly dependent on observer skills, inducing high interobserver and intraobserver variation that affects the utility of these diagnostic modalities. Objective and reliable methods of detecting optic nerve head and RNFL pathologies, and their progression as well, would help the clinician in the diagnosis and monitoring of glaucomatous damage. Researches during the past two decades have resulted in the development of several imaging technologies designed to detect glaucomatous damage at early stages of disease. This review outlines optical coherence tomography (OCT), which is a noncontact noninvasive imaging technology that can create high-resolution, real-time, cross-sectional tomographic images of retina and optic nerve head using light with a wavelength of ~800 nm. Cross-sectional images of the optic disc and retina are obtained using the optical backscattering of near-infrared light in a manner analogous to B-scan ultrasonography. OCT can differentiate the anatomic layers of retina, measure the thickness of RNFL and produce the optic nerve head parameters. Thus, OCT has became a widely used imaging modality that enables clinicians to obtain objective measurements of RNFL thickness and optic nerve head parameters in glaucoma. Keywords : Optical coherence tomography, glaucoma
PureSee Kesintisiz Yüksek Kalitede Görüş
Home
About The Journal
Editorial Board
Instructions for Authors
Contact